Programming
Control
9.
Audio Signal
"Aud"
or
"AUd"*
*"Aud" is displayed for control software version
01
and "AUd" is displayed for control software version
02 or later.
This option allows the owner to program when the
signal will sound.
There are six occasions when a signal may sound
during the dryer operation. These six occasions are
listed below:
1.
End
of
Cycle Signal
By
default, the signal is turned off.
If
turned on,
the signal will sound for three seconds at the end
ofacycle.
2.
Keypad
Depression Signal
By
default, this signal is turned on and will sound
for a quarter
of
a second. This signal will sound
each time a keypad is pressed.
3.
Coin
Input/Card
Insertion
Signal
By
default, this signal is turned on and will sound
for a quarter
of
a second each time a coin or card
is entered.
4. Remove
Card
Signal
(Card
Models Only)
By
default, this signal is turned on and will sound
one second
on
and one second
off
when the
control is prompting for card removal.
S.
Signal
for
Start
By
default, this signal is turned on and will sound
one second
on
and one second
off
for
10
seconds
when START LED is flashing after vend price
has been satisfied.
6.
Extended
Tumble
Mode
Signal
This signal cannot
be
disabled. While in
extended tumble mode, the signal will sound one
second on and one second
off
for five seconds
and then continuously for five seconds before
starting the extended tumble.
How
to
Program the Audio Signal
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2.
Press the
WW
TEMP
(1\)
or the
DELICATES
(v)
keypad until
"Prog"
appears in
the display. Press the START (enter) keypad and
"AtSH" will appear
in
the display.
3. Press the LOW TEMP
(1\)
or the
DELICATES
(v)
keypad to scroll through the
programmable options until "Aud" or "AUd"
(depending on control software version) appears
in the display.
4. When
"Aud"
or "AUd" appears
in
the display
press the START (enter) keypad. A number will
appear in the display. This number corresponds to
the current Audio Signal Programming Value.
S.
Locate the desired number in the first column
of
Table 4 on the following page.
6.
Press the LOW TEMP
(1\)
or the
DELICATES
(v)
keypad to increase
or
decrease
the current number until correct.
For Example: A user might wish to have the signal
sound only when a keypad is pressed. Entering the
number
"I"
in step S would turn
off
all the options
except KEYPAD. In this instance, the signal would
sound only when a keypad is pressed.
7. Press the START (enter) keypad when the correct
number appears in the display. The new value is
saved and the next option,
"CArd", will appear in
the display.
NOTE:
To
program
"CArd"
(Card
Reader
Display
Control),
refer
to
option 10. To
program
other
options,
refer
to
the
appropriate
section.
How
to
Exit Programming Feature
Press the MED TEMP
«)
keypad until the control
returns to Ready Mode.