31. Manual Diagnostics (On/Off)
"dAEn"
This option allows the owner
to
enable
or
disable the
manual diagnostics option. Refer to
Testing Machine
and
Electronic Control Functions section for more
infonnation.
How
to
Program the Manual Diagnostics
(On/Off)
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the LOW TEMP (/\) or the
DELICATES
(v)
keypad until "Prog" appears in
the display. Press the START (enter) keypad and
"AtSH" will appear in the display.
3. Press the LOW TEMP (/\)
or
the
DELICATES
(v)
keypad to scroll through the
programmable options until
"dAEn"
appears in
the display.
4. When
"dAEn"
appears in the display, press the
START (enter) keypad. The current Manual
Diagnostics status will appear in the display.
"on"
= Option Enabled
"oFF"
= Option Disabled
NOTE: The default value is on.
5. Press the LOW TEMP (/\)
or
the
DELICATES
(v)
keypad to change the current
status.
6. Press the START (enter) keypad when the
desired status appears
in the display. The new
value is saved and the next option,
"PtEn",
will
appear in the display.
NOTE:
To
program
"PtEn"
(production Test Cycle
(OnlOff]), refer
to
option 32.
To
program
other
options,
refer
to the appropriate section.
How
to
Exit Programming Feature
Press the MED TEMP
«)
keypad until the control
returns to Ready Mode.
Programming Control
32. Production Test Cycle (On/Off)
"PtEn"
This option allows the owner to enable or disable
access to the production test cycle. Refer
to
Production Test Cycle section for more information.
How
to
Program the Production Test
Cycle (On/Off)
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2.
Press the LOW TEMP (/\) or the
DELICATES
(v)
keypad until "Prog" appears in
the display. Press the START (enter) keypad and
"AtSH" will appear in the display.
3. Press the LOW TEMP (/\) or the
DELICATES
(v)
keypad to scroll through the
programmable options until
"PtEn"
appears in
the display.
4. When
"PtEn"
appears in the display, press the
START (enter) keypad.
The
current Production
Test Cycle status will appear in the display.
"on"
= Option Enabled
"oFF"
= Option Disabled
NOTE:
The
default value is on.
5. Press the LOW TEMP (/\)
or
the
DELICATES
(v)
keypad to change the current
status.
6. Press the START (enter) keypad when the
desired status appears in the display. The new
value is saved and the next option,
"AtSH", will
appear in the display.
NOTE:
To
program
"AtSH"
(Heat Vend Price),
refer to
option 1.
To
program
other
options, refer to
the
appropriate
section.
How
to
Exit Programming Feature
Press the MED TEMP
«)
keypad until the control
returns to Ready Mode.
513001
© Published by pennission
of
the copyright owner - DO NOT COPY
or
TRANSMIT
63