Programming Control
13. Cycle Time "CyC-"
This option allows the owner to set the amount
of
time
for all cycles.
How
to
Program Cycle Time
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2.
Press the
LOW
TEMP (1\)
or
the
DELICATES
(v)
keypad until
"Prog"
appears
in
the display. Press the START (enter) keypad
and
"AtSH" will appear
in
the display.
3. Press the
LOW
TEMP (1\)
or
the
DELICATES
(v)
keypad to scroll through the
programmable options until
"CyC-"
appears in
the display.
4. When
"CyC-"
appears in the display, press the
START (enter) keypad. There are four
programmable cycle time options.
Refer to Table
7.
5. Press the LOW TEMP (1\)
or
the
DELICATES
(v)
keypad to select the desired
cycle time option.
NOTE: Cycle time can be set from one
(1)
to 99
minutes.
NOTE: The default value for both cycles in minutes
is 45 and the default value for seconds is
O.
6. Press the START (enter) keypad when the correct
option appears in the display.
7. Press the LOW TEMP
(1\)
or
the
DELICATES
(v)
keypad to increase
or
decrease
the number
of
minutes
or
seconds displayed to
the desired number
of
minutes
or
seconds.
8. Press the START (enter) keypad when the correct
number
of
minutes
or
seconds appears in the
display. The new value is saved and the next
option in the parameter will appear
in
the display.
NOTE:
To
program the next option, "Cdt·"
Display
"CyC1"
"CyC2"
"CyC3"
"CyC4"
Cycle Time Options
I
I
(Cooldown Time), press the MED
TEMP
«)
keypad until "CyC-" is displayed, then press the
Heat Cycle Time Minutes
Heat Cycle Time Seconds
No
Heat Cycle Time Minutes
LOW
TEMP (A)
or
DELI CATES (v) keypad until
"Cdt·" appears in the display
and
refer to
option 14.
To
program other options, refer to the
appropriate section.
No
Heat Cycle Time Seconds
Table
7
How
to
Exit Programming Feature
Press the MED TEMP
«)
keypad until the control
returns to Ready Mode.