Programming Control
29. IR Access (On/Off)
"IrA"
This option allows the owner to enable or disable
allowing the control to
be
read
by
an external device.
How
to
Program the IR Access (On/Off)
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the LOW TEMP
(1\)
or the
DELICATES
(v)
keypad until
"Prog"
appears in
the display. Press the START (enter) keypad and
"AtSH" will appear in the display,
3. Press the LOW TEMP
(1\)
or the
DELICATES
(v)
keypad to scroll through the
programmable options until
"IrA" appears in the
display.
4. When
"IrA" appears in the display, press the
START (enter) keypad. The current IR Access
status will appear in the display.
"on"
=Option Enabled
"oFF"
= Option Disabled
NOTE:
The
default value is on.
5. Press the LOW TEMP
(1\)
or
the
DELICATES
(v)
keypad to change the current
status.
6.
Press the
START
(enter) keypad when the
desired status appears in the display. The new
value is saved and the next option,
"rAEn", will
appear in the display.
NOTE:
To
program
"rAEn"
(Manual
Rapid
Advance
[OnlOff),
refer
to
option 30. To
program
other
options,
refer
to
the
appropriate
section.
How
to
Exit Programming Feature
Press the MED TEMP
«)
keypad until the control
returns to Ready Mode.
30.
Manual Rapid Advance (On/Off)
"rAE.,"
This option allows the owner to enable or disable the
rapid advance feature. Refer to
Rapid Advance
Feature
section for more information.
How
to
Program the Manual Rapid
Advance (On/Off)
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2.
Press the LOW TEMP
(1\)
or the
DELICATES
(v)
keypad until
"Prog"
appears in
the display. Press the START (enter) keypad and
"AtSH" will appear in the display.
3. Press the LOW TEMP
(1\)
or
the
DELICATES
(v)
keypad to scroll through the
programmable options until "rAEn" appears in
the display.
4. When "rAEn" appears in the display, press the
START (enter) keypad. The current Manual
Rapid Advance status will appear in the display.
"on"
= Option Enabled
"oFF"
=Option Disabled
NOTE:
The
default value is on.
5. Press the LOW TEMP
(1\)
or the
DELICATES
(v)
keypad to change the current
status.
6.
Press the START (enter) keypad when the
desired status appears in the display. The new
value is saved and the next option,
"dAEn", will
appear in the display.
NOTE:
To
program
"dAEn"
(Manual
Diagnostics
[OnlOff]),
refer
to option 31. To
program
other
options,
refer
to
the
appropriate
section.
How
to
Exit Programming Feature
Press the MED TEMP
«)
keypad until the control
returns to Ready Mode.
62
© Published by permission of the copyright owner - DO NOT
COpy
or TRANSMIT
513001