Duct Station
Minimum Diameter
of
Collector Duct
A
10.2 cm (4 inches)
B
20.3 cm (8 inches)
C 22.9 cm (9 inches)
D
25.4 cm
(to
inches)
E
27.9
cm
(11
inches)
F
30.5 cm (12 inches)
G 32.6 cm (13 inches)
H
35.6 cm (14 inches)
I
38.1 cm (15 inches)
J
38.1
cm
(15 inches)
K
40.6 cm (16 inches)
A Backdrafi Damper, Part No. 58786 (obtain locally),
should
be
installed in a 10.2 em (4 inch) diameter
VERTICAL duct system. This will prevent a backdraft
when dryer is not in use, and will keep the exhaust air
in balance within the central exhaust system.
Step 3: (Gas Dryer Only) Connect Gas
Supply Pipe
AI
WARNING
To reduce the risk
of
gas leaks, fire
or
explosion:
The dryer
must
be connected
to
the type
of
gas as shown
on
nameplate located
in
the
door
recess.
Use a new flexible stainless steel
connector.
Use pipe
joint
compound insoluble
in
L.P.
(Liquefied Petroleum) Gas,
or
Teflon tape,
on
all pipe threads.
Purge
air
and sediment from gas
supply
line before connecting
it
to
the dryer.
Before tightening the connection, purge
remaining
air
from
gas line
to
dryer
until
odor
of
gas
is
detected. This step
is
required
to
prevent gas valve
contamination.
Do
not
use an open flame
to
check
for
gas
leaks. Use a non-corrosive leak detection
fluid.
Any
disassembly requiring the use
of
tools
must
be performed
by
a suitably
qualified service person.
W316
Installation
1.
Make certain your dryer is equipped for use with
the type
of
gas in your laundry room. Dryer is
equipped at the factory for
Natural
Gas
with a
3/8 inch
NPT
gas connection.
NOTE:
The
gas
service to a gas
dryer
must
conform
with
the
local codes
and
ordinances,
or
in
the
absence
of
local codes
and
ordinances,
with
the
latest
edition
of
the
National
Fuel
Gas
Code
ANSI
Z223.11NFPA 54
or
the
CAN/CSA-B149.1,
Natural
Gas
and
Propane
Installation Code.
Natural
Gas, 37.3 MJ/m
3
(1000 Btu/fi3) service must
be
supplied
at
minimum 5.0 inch water column
pressure to a maximum 10.5 inch water column
pressure.
For proper operation at altitudes above 610 m
(2000 feet) the natural gas valve spud orifice size must
be
reduced to ensure complete combustion. Refer
to
Table
2.
Natural Gas Altitude Adjustments
Altitude Orifice Size
Part
Number
feet inches
503776
2,000
41
2.44 0.0960
610
0.0935 503777
1,680
915 3,000 42 2.37
0.0890 503778
2,135
5,500 43 2.26
0.0860 58719
2,745
7,000 44 2.18
0.0820 503779
10,500
9,000 45 2.08
0.0810 503780
46 2.06
Table
2
2. Remove the shipping cap from the gas
connection
at
the rear
of
the dryer. Make sure you
do not damage the pipe threads when removing
the cap.
3. Connect to gas supply pipe.
513082