Error Codes
Table
18
(Continued)
Display Description
Causel
Corrective Action
EC19
No Card Reader Communication and
No Card Reader Initialization
Communication failure. Power down, power up, check
connections and
try again.
If
error persists, replace control
or card reader.
EC36
Audit Card Removed Prematurely Re-insert Audit Card and wait until machine prompts for
card removal.
Rightmost
. decimal
• point Lit
Network Communication Error
Communication problem. Wait for
1.5
minutes for error to
clear.
If
error doesn't clear, power-down and power-up the
machine. Check all network connections.
If
error persists,
replace control or network board.
ALrn
Break-in Alarm Error Service the service door or coin vault switches.
oFF
Break-in Alarm Shutdown Error Service the service door or coin vault switches.
Err
Coin Error Invalid coin pulse or inoperative coin sensor. Check coin
drop area and remove obstructions.
If
error persists,
tampering may have occurred. Evaluate security
procedures.
ESH
Shorted Thennistor Error Remove any lint build-up around thennistor. Ifproblem
persists, replace control or thennistor.
EoP
Open Thennistor Error Remove any lint build-up around thermistor. Ifproblem
persists, replace control or thermistor.
Table