Programming Control
(continued)
Option
Option
Description
Factory Default
Value Range
Number Display
26
"CnP-"
Cycle Modifier Programming
-
-
a
"CnP1"
Cycle Modifier Medium Price
25
0-65,535
b
"CnP2"
Cycle Modifier Heavy Price
50
0-65,535
c
"CnP3"
Cycle Modifier Medium Option
2
0-15
d
"CnP4"
Cycle Modifier Heavy Option
3
0-15
e
"CnP5"
Cycle Modifier Added Wash Time
2
0-15
*f
"CnP6"
Default Cycle Modifier
0
0-2
*27 "PCt-"
Cycle Time Display
-
*a
"PCtE"
Cycle Time Display Enable
oFF
,
*b
"PCt1"
Cycle
#1
Time
34
0-255
*c
"PCt2"
Cycle #2 Time
34
0-255
*d
"PCt3"
Cycle
#3
Time
1
32
0-
255
28
"droP"
Drop
Off
Mode (On/Off)
oFF on/oFF
29 "LPSA"
Low Power! Auto Shutdown A Days
oFF
on/oFF
Enable
(On/Off)
30
"LPSb"
Low Power! Auto Shutdown B Days
oFF
on/oFF
Enable (On/Off)
131
"LPSC"
Low Power! Auto Shutdown C Days
oFF
on/oFF
Enable (On/Off)
32
"LPSd"
Low Power! Auto Shutdown D Days oFF on/oFF
Enable (On/Off)
33 "PFr"
Power Fail Reset
oFF oFF!133 - 255
34 IR Access (On/Off)
on on/oFF
35
"rAEn"
Manual Rapid Advance (On/Off)
on on/oFF
36
"dAEn"
Manual Diagnostics (On/Off)
on
on/oFF
37
"PtEn"
Production Test Cycle (On/Off)
on on/oFF
* This option available
in software version
"S
02" or higher only.
802952
© Published by permission
of
the copyright owner - DO NOT
COPY
or
TRANSMIT
17