GS980MX Series Installation Guide for Virtual Chassis Stacking
195
Verifying the
Master
GS980MX/
52PSm Switch
Perform the steps in Table 33 to confirm the configuration of the master
switch.
6
Designate the ports as stacking ports with the STACKPORT command.
awplus(config-if)# stackport
% Save the config and restart the system for this change to take effect.
Steps 7 to 13 save your changes on the master switch and reboot it.
7
Return to the Global Configuration mode.
awplus(config-if)# exit
8
Return to the Privileged Exec mode.
awplus(config)# exit
9
Enter the WRITE command to save your changes.
awplus# write
Building configuration ...
[OK]
10 Restart the switch with the REBOOT command.
awplus# reboot
reboot system? (y/n):
awplus#
11 Type “Y” for yes.
12 Wait two minutes for the switch to initialize the management software.
13 Go to “Verifying the Master GS980MX/52PSm Switch” on page 195.
Table 32. Configuring the Master GS980MX/52PSm Switch for 5Gbps Stacking Ports – Part II
Step Description and Command
Table 33. Verifying the Master GS980MX/52PSm Switch
Step Description and Command
1 Start a new local management session on the master switch.
2 Move to the Privileged Exec mode with the ENABLE command.
awplus> enable