EasyManuals Logo

Allied Telesis AlliedWare Plus GS980MX Series User Manual

Allied Telesis AlliedWare Plus GS980MX Series
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #205 background imageLoading...
Page #205 background image
GS980MX Series Installation Guide for Virtual Chassis Stacking
205
Configuring
Member
GS980MX/
10HSm Switches
– Part II
This section contains instructions to the second part to configuring
member switches. The instructions explain how to configure the following
parameters:
Set the priority number. For background information, refer to
“Configuring the Member Switch” on page 201.
Designate the stacking ports for the stack trunk. Refer to “Stack
Trunks” on page 63.
To configure a member switch, perform the procedure in Table 35.
13 Check the ID LED on the front panel and do one of the following:
- If the ID LED is displaying the switch’s new ID number, go to “Configuring Member
GS980MX/10HSm Switches – Part II,” next.
- If the ID LED is displaying a different number, repeat this procedure. Be sure to
correctly enter the STACK RENUMBER command and to save your changes with the
WRITE command.
14 Go to “Configuring Member GS980MX/10HSm Switches – Part II” on page 205.
Table 34. Configuring Member GS980MX/10HSm Switches – Part I (Continued)
Step Description and Command
Table 35. Configuring Member GS980MX/10HSm Switches – Part II
Step Description and Command
1 Start a new local management session on the member switch. Refer to “Starting a
Local Management Session” on page 150.
2 Enter the ENABLE command to move from the User Exec mode to the Privileged
Exec mode.
awplus> enable
Steps 3 and 4 set the switch’s priority value to be the same as its ID number.
3 Move to the Global Configuration mode with the CONFIGURE TERMINAL command.
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
4 Assign a priority value to the switch equal to its ID number, with the STACK
PRIORITY. This example assigns priority 2 to a member switch with the ID 2:
awplus(config)# stack 2 priority 2
Steps 5 and 6 remove the stacking function from the default 10Gbps stacking ports on the
member switch.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus GS980MX Series and is the answer not in the manual?

Allied Telesis AlliedWare Plus GS980MX Series Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus GS980MX Series
CategorySwitch
LanguageEnglish

Related product manuals