EasyManuals Logo

Allied Telesis AlliedWare Plus GS980MX Series User Manual

Allied Telesis AlliedWare Plus GS980MX Series
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #241 background imageLoading...
Page #241 background image
GS980MX Series Installation Guide for Virtual Chassis Stacking
241
Problem 5: The SHOW STACK command is not displaying all the
switches in the stack.
Solutions: If you are using 10Gbps ports for the stack trunk, try the
following:
Verify that the stacking ports are properly cabled. Refer to
Chapter 10, “Cabling the Networking Ports” on page 231.
If you are using SFP+ transceivers for the stack trunk, verify that
they are fully inserted into the transceiver ports.
If you are using SPI0TW direct connect twinax cables, verify that
they are from Allied Telesis. The trunk will not work with cables
from other network equipment manufacturers.
Verify that VCStack is activated on the switches. For instructions,
refer to Chapter 7, “Building the Trunk with the Default 10Gbps
Stacking Ports” on page 141.
Problem 6: The GS980MX/10HSm, GS980MX/18HSm, GS980MX/
28PSm or GS980MX/52PSm switch is not providing power to a PoE
device.
Solutions: Try the following:
Check the port’s PoE LED. If the LED is flashing amber, the switch
has reached its maximum power budget and cannot support any
additional PoE devices.
Review the powered device's documentation to verify that it is
compatible with the switch. Refer to “Powered Device Classes” on
page 45 and“Wiring Implementation” on page 47.
Use the SHOW SYSTEM ENVIRONMENT command to confirm
that both power supplies are operating normally.
Use the management software to determine whether the switch
has reached its maximum power budget and cannot support any
further powered devices. The maximum power budget is:
GS980MX/10HSm: 500W with one power supply
GS980MX/18HSm: 720W with one power supply
GS980MX/28PSm: 370W with one power supply
GS980MX/52PSm: 370W with one power supply
Verify that you are using the appropriate category of twisted-pair
cable by referring to “Cable Requirements” on page 34.
Use the management software on the switch to determine whether
PoE is enabled on the port. The default setting for PoE is enabled.
Use the management software on the switch to determine whether
the PoE power setting for the port has been reduced to a value
below the power requirements of the device.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus GS980MX Series and is the answer not in the manual?

Allied Telesis AlliedWare Plus GS980MX Series Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus GS980MX Series
CategorySwitch
LanguageEnglish

Related product manuals