Cleaning, maintenance and repairs
158
Condor 12001-C/15001-C BAH0030-4 07.15
What should be observed when cleaning with a high-pressure
cleaner/steam cleaner:
Do not clean any electrical components.
Do not clean any chromed components.
Never aim the cleaning jet from the nozzle of the high pressure
cleaner/steam jet directly on lubrication points, bearings, rating
plates, warning signs, and stickers.
Always maintain a minimum nozzle distance of 300 mm between
the high pressure cleaner/steam jet cleaner nozzle and the
implement.
The set pressure of the high-pressure cleaner/steam jet must
not exceed 120 bar.
Comply with safety regulations when working with high pressure
cleaners.
1. Fully extend or retract the implement before cleaning it (see
section 10.1, Seite 138).
Never clean the implement if the rear frame and implement
booms are not completely folded.
2. To clean, always place the implement coupled to the tractor on
the jack (Fig. 196).
3. Apply the tractor parking brake, switch the tractor engine off and
remove the ignition key.
4. Empty the hopper and the metering units (see section "Emptying
the hopper and/or metering unit.", Seite 153).
5. Clean the distributor head [see section "Clean the distributor
head", Seite 159].
6. Clean the implement with water or with a high pressure cleaner.