EasyManuals Logo

Amazone Condor 12001-C User Manual

Amazone Condor 12001-C
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #186 background imageLoading...
Page #186 background image
Cleaning, maintenance and repairs
186
Condor 12001-C/15001-C BAH0030-4 07.15
12.5.8.5 Checking the pressure in the compressed air tank of the dual-circuit pneumatic
braking system (specialist workshop)
1. Connect a pressure gauge to the test connection on the
compressed air tank.
2. Run the tractor engine (approx. 3 mins.) until the compressed air
tank has filled.
3. Check whether the pressure gauge is displaying the setpoint
range 6.0 to 8.1 bar.
4. If the reading drops below or exceeds the setpoint range, have
the defective parts of the braking system replaced in a specialist
workshop.
12.5.8.6 Leak test of the dual-circuit pneumatic braking system (specialist workshop)
Test all connections, pipe, hose and screw unions for seal-
tightness
Eliminate any abrasion points on pipes and hoses
Replace any porous and damaged hoses (specialist workshop)
The dual-circuit pneumatic braking system is considered free of
leaks if the pressure drop within 10 minutes with the engine shut
down is no greater than 0.10 bar, i.e. about 0.6 bar per hour.
If the values are not maintained, have the leakage sealed or the
defective components of the brake system replaced at a
specialist workshop.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amazone Condor 12001-C and is the answer not in the manual?

Amazone Condor 12001-C Specifications

General IconGeneral
BrandAmazone
ModelCondor 12001-C
CategoryFarm Equipment
LanguageEnglish

Related product manuals