5.6.1 Digital fill level monitoring
A fill level sensor monitors the fertiliser level in
the hopper.
When the level reaches the fill level sensor
The control symbol (Fig. 52/1) marks the fill
level symbol on the AMALOG
+
An alarm signal is issued.
This alarm signal is intended to remind the
tractor driver to refill the seed.
Fig. 52
Each hopper chamber has a fill level sensor.
Adjust the height of each fill level sensor (Fig. 53/1) individually. As
soon as a level reaches a fill level sensor, the AMALOG
+
issues an
alarm.
The height of the fill level sensor (Fig. 53/1) can
be adjusted from the outside by fastening in one
of the brackets.
Attach the fill level sensor according to the type
of seed.
Fig. 53
Grains and legumes:
Fit the sensor to the higher bracket.
Fine seed types (e.g. rape):
Fit the sensor to the lower bracket.
Fertilisers:
Attach the sensor in the upper or lower bracket,
depending on the spread rate.
This allows the residual seed volume to be set,
at which the warning message and the alarm
signal is to be issued.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amazone Condor 12001-C and is the answer not in the manual?

Amazone Condor 12001-C Specifications

General IconGeneral
BrandAmazone
ModelCondor 12001-C
CategoryFarm Equipment
LanguageEnglish

Related product manuals