Page #155 background image
Faults
Condor 12001-C/15001-C BAH0030-4 07.15
155
11 Faults
WARNING
Danger of crushing, shearing, cutting, being caught or drawn in,
winding and knocks through:
unintentional falling of the implement raised using the
tractor's three-point hydraulic system.
unintentional lowering of raised, unsecured implement
parts.
unintentional start-up and rolling of the tractor-implement
combination.
Secure the tractor and the implement against unintentional start-up
and rolling, before you eliminate any faults on the implement. On this
subject see section 6.2, Seite 92.
Wait for the implement to stop, before entering the implement danger
area.
11.1 Display of amount remaining
When the seed level reaches the fill level sensor
The control symbol (Fig. 195/1) marks the
fill level symbol on the AMALOG
+
An alarm signal is issued.
Fig. 195
11.2 Fault table
Fan sensor alarmed Alarm limit is not correctly set Alter the alarm limit
Oil volume too low or too high Set the oil volume
Fan sensor defective Replace the fan sensor
Distance sensor
(star wheel/Vario gearbox)
not functioning
Distance sensor defective Replace the distance sensor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amazone Condor 12001-C and is the answer not in the manual?

Amazone Condor 12001-C Specifications

General IconGeneral
BrandAmazone
ModelCondor 12001-C
CategoryFarm Equipment
LanguageEnglish

Related product manuals