9.1.8 Adjusting the cutting disc distance on the FerTeC Twin coulter
INTERVAL
Every 100 operating hours
or
as required
With increasing wear of the cutting discs, the distance
between the cutting discs also increases.
1. Remove the dust caps
.
2. Unscrew and remove the central bolts
.
NOTE
The central bolts have different threads:
The right central bolt has right-hand thread
The left central bolt has left-hand thread
3. To ensure that the cutting discs
touch
slightly,
remove or add spacer discs
as required.
4. Install spacer discs that are not required on the
opposite side of the cutting disc bearing with the
central bolt.
5. Put on and tighten the central bolt.
6. Install the dust caps.
CMS-I-00002019
9.1.9 Checking and replacing the inner scraper on the FerTeC Twin coulter
INTERVAL
Every 100 operating hours
or
Every 3 months
The inner scrapers ensure smooth coulter running
and are subject to wear.
CMS-T-00002380-D.1
CMS-T-00002381-C.1
9 | Repairing the machine
Maintaining the machine
MG6660-EN-II | D.1 | 27.09.2021
190