NOTE
With an electric drive, the target spacing can be
adjusted via the forward speed.
The minimum target spacing is based on the
maximum working speed, the maximum singling
unit speed, and the largest singling disc.
The maximum target spacing is based on the
minimum working speed, the minimum singling
unit speed, and the smallest singling disc.
Drive Speed range [rpm] Target spacing [cm]
Electric drive 2 - 55 3.8 - 49
Mechanical drive, trailing
55, depending on the forward
speed
4.6 - 37.7
Mechanical drive, leading
55, depending on the forward
speed
2.3 - 37.7
Seed hopper [litres]
55/70
5.4.2 Fertiliser metering unit
NOTE
With an electric drive, the spread rate can be
adjusted via the forward speed.
The maximum spread rate depends on the
metered material. The maximum spread rate is
based on a working speed of 15 km/h.
Drive Maximum spread rate [kilograms / ha]
Electric drive 250
Mechanical drive 250
Fertiliser hopper [litres]
950 / 1250
CMS-T-00002362-D.1
5 | Technical data
Metering unit
MG6660-EN-II | D.1 | 27.09.2021
49

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amazone Precea 3000 and is the answer not in the manual?

Amazone Precea 3000 Specifications

General IconGeneral
BrandAmazone
ModelPrecea 3000
CategoryFarm Equipment
LanguageEnglish

Related product manuals