9.1.23 Cleaning the filling auger
INTERVAL
Every 100 operating hours
or
Every 12 months
REQUIREMENTS
The implement is coupled to the tractor
The fan is switched off
The filling auger is switched off
The tractor and implement are secured
1. Place a collection bucket
1
under the conveyor
tube.
2. Loosen the nuts
3
and remove them.
3. Remove the cover
2
.
4. Knock out the fertiliser residue from the conveyor
tube and collect it.
1
2
3
21
CMS-I-00002026
5. Unscrew and remove the bolts
1
.
6. Remove the installation flap
2
.
7. Thoroughly clean the filling auger
3
with a water
jet.
8. Put on the installation flap.
9. Put on the bolts and tighten them.
10. Install the cover.
11. Put on the nuts and tighten them.
1
2
3
CMS-I-00002027
CMS-T-00002391-A.1
9 | Repairing the machine
Maintaining the machine
MG6660-EN-II | D.1 | 27.09.2021
200

Table of Contents