Hydraulic system
Maximum operating pressure 210 bar
Tractor pump output
Implement with mechanical fan drive, at least 20 l/min at 150 bar
Implement with hydraulic fan drive, at least 50 l/min at 150 bar
Implement hydraulic oil
HLP68 DIN51524
The hydraulic oil is suitable for the combined hydraulic oil circuits
of all standard tractor manufacturers.
Control units Depending on the implement equipment
Pressure-free return flow Do not exceed a back pressure of 5 bar.
5.10 Noise development data
The workplace-related emission sound pressure level
is lower than 70 dB(A), measured in operating
condition at the ear of the tractor driver with the cab
closed.
The emission sound pressure level mainly depends
on the vehicle used.
5.11 Drivable slope inclination
Across the slope
On left in direction of travel 15%
On right in direction of travel 15%
Up the slope and down the slope
Up the slope 15%
Down the slope 15%