8. Turn the lock beyond the notch
2
.
The points
1
and
3
are no longer aligned.
1
3
2
CMS-I-00001911
9. Close the cover
2
.
NOTE
Pay attention to the guide pin
1
.
10. Close the locks.
2
1
CMS-I-00001913
9.1.29 Cleaning the opto-sensor
INTERVAL
Every 50 operating hours
or
as required
1. Disconnect the ISOBUS connection to the tractor.
2. Open the locks
1
.
3. Remove the cover
2
.
1
2
CMS-I-00001909
CMS-T-00002393-C.1
9 | Repairing the machine
Maintaining the machine
MG6660-EN-II | D.1 | 27.09.2021