EasyManua.ls Logo

Amazone Precea 3000 - Cleaning the Cyclone Separator

Amazone Precea 3000
254 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REQUIREMENTS
The implement is coupled to the tractor
The singling unit housings are open
The singling discs are removed
1. Open the water drain
1
on the air distributor.
2. To wash the deposits from the blower fan rotors,
Direct a jet of water into the suction opening
2
.
3. When most of the water has escaped through
the air distributor,
run the fan for about 5 minutes.
The air supply is blown dry.
4. Switch off the fan.
5. Close the water drain on the air distributor.
1
2
CMS-I-00002024
9.1.21 Cleaning the cyclone separator
INTERVAL
Every 10 operating hours
or
daily
For the cyclone separator to work, the separator
opening
3
must be free of impurities.
1. Check the separator opening
3
.
2. If the separator opening in clogged,
open the clips
2
.
3. Loosen the wing nut
1
.
4. Remove the cover and clean it.
5. Install the cover with the wing nut.
6. Fasten the suction cage with the clips.
1
2
3
CMS-I-00002765
CMS-T-00003779-B.1
9 | Repairing the machine
Maintaining the machine
MG6660-EN-II | D.1 | 27.09.2021
198

Table of Contents

Related product manuals