REQUIREMENTS
The implement is coupled to the tractor
The singling unit housings are open
The singling discs are removed
1. Open the water drain
1
on the air distributor.
2. To wash the deposits from the blower fan rotors,
Direct a jet of water into the suction opening
2
.
3. When most of the water has escaped through
the air distributor,
run the fan for about 5 minutes.
The air supply is blown dry.
4. Switch off the fan.
5. Close the water drain on the air distributor.
1
2
CMS-I-00002024
9.1.21 Cleaning the cyclone separator
INTERVAL
Every 10 operating hours
or
daily
For the cyclone separator to work, the separator
opening
3
must be free of impurities.
1. Check the separator opening
3
.
2. If the separator opening in clogged,
open the clips
2
.
3. Loosen the wing nut
1
.
4. Remove the cover and clean it.
5. Install the cover with the wing nut.
6. Fasten the suction cage with the clips.
1
2
3
CMS-I-00002765
CMS-T-00003779-B.1
9 | Repairing the machine
Maintaining the machine
MG6660-EN-II | D.1 | 27.09.2021
198

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amazone Precea 3000 and is the answer not in the manual?

Amazone Precea 3000 Specifications

General IconGeneral
BrandAmazone
ModelPrecea 3000
CategoryFarm Equipment
LanguageEnglish

Related product manuals