8.3 Emptying the seed hopper through the residual quantity flap
REQUIREMENTS
The implement is coupled to the tractor
The tractor and implement are secured
NOTE
The parking position for the chute is in the hopper
cover for row 1.
1. Take out the chute
1
.
1
CMS-I-00001888
2. Hook the chute
1
onto the singling unit.
NOTE
When the collection bucket is hooked onto the
chute, the chute can be loaded with a maximum
of 12 kg.
3. Put the collection bucket
2
under the chute
or
Hook the collection bucket
2
onto the chute.
2
1
CMS-I-00001995
4. Open the locking spring
1
.
The flap
2
is opened and the residual quantity is
collected.
5. When the residual quantity has been collected,
park the chute back into the hopper cover.
6. Close the flap.
7. Lock the locking spring.
1
2
CMS-I-00001996
CMS-T-00001917-B.1
8 | Parking the machine
Emptying the seed hopper through the residual quantity flap
MG6660-EN-II | D.1 | 27.09.2021