NOTE
Set the gearbox setting lever between the scale
positions 20 and 80.
3. Set the gearbox setting lever to the value read
from the disc.
The sliding shutter is completely open
1
The sliding shutter is opened to
1
/
3
2
The sliding shutter is closed
3
CMS-I-00002689
4. If the setting range is between 0.1 and 5,
move the sliding shutter for the fertiliser metering
unit to position
2
.
The supply to the metering unit is reduced.
5. Repeat the calibration.
6.4.17
Changing the application rate for liquid fertiliser
The liquid fertiliser metering unit
1
is connected to
the tank via the supply hose
3
. The liquid fertiliser
flows through the hose
2
into the fertiliser coulter
and is applied in the soil.
CMS-I-00002729
CMS-T-00003722-A.1
6 | Preparing the machine
Preparing the implement for operation
MG6660-EN-II | D.1 | 27.09.2021