9.1.19 Checking the hydraulic hose lines
INTERVAL
After initial operation
Every 50 operating hours
or
weekly
1. Check the hydraulic hose lines for damage, such
as chafing point, cuts, tears and deformation.
2. Check the hydraulic hose lines for leaks.
Hydraulic hose lines must not be more than 6 years
old.
3. Check the manufacturing date
1
.
CMS-I-00000532
4. Have any worn, damaged or aged hydraulic
hose lines immediately replaced at a specialist
workshop.
5. Retighten loose bolted connections.
9.1.20 Cleaning the fan rotor
INTERVAL
Every 50 operating hours
or
as required
The air drawn by the fan can contain fertiliser dust
or sand. These impurities can accumulate on the
fan rotors and cause imbalance of the fan. This can
destroy the fan.