24. Close the fertiliser hopper tarpaulin.
25. Secure the fertiliser hopper tarpaulin with rubber
straps.
9.1.25
Cleaning the fertiliser metering unit
INTERVAL
Every 10 operating hours
or
daily
REQUIREMENTS
The implement is coupled to the tractor
The fan is switched off
The filling auger is switched off
1. To close the fertiliser hopper on the metering
housing,
close the sliding shutter
1
.
2. Take the unlocking tool from the threaded
cartridge or the parking position on the fertiliser
hopper.
3. To unlock the metering unit cover,
insert the unlocking tool
2
into the metering unit
cover.
4. Open the metering unit cover
3
with the
unlocking tool.
5. Remove residues or foreign objects from the
metering housing.
6. Close the metering unit cover
3
.
7. Park the unlocking tool from the threaded
cartridge or the parking position in the fertiliser
hopper.
2
1
3
CMS-I-00002256
CMS-T-00002473-C.1
9 | Repairing the machine
Maintaining the machine
MG6660-EN-II | D.1 | 27.09.2021
203

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amazone Precea 3000 and is the answer not in the manual?

Amazone Precea 3000 Specifications

General IconGeneral
BrandAmazone
ModelPrecea 3000
CategoryFarm Equipment
LanguageEnglish

Related product manuals