1. Put the seed in the reference holes
.
2. If the seed lies loosely on the reference hole,
read the hole diameter.
CMS-I-00001217
6.4.10.2 Checking the grain spacing
The spread rate determines the required grain
spacing. The grain spacing is adjusted by selecting
the singling discs and adjusting the singling disc
speed.
CMS-I-00002011
1. Seed approx. 30 m at working speed.
2. Use the read-off edge of the multi-placement
tester to remove the earth in layers.
3. Expose 11 grains in one row.
4. Place the multi-placement tester horizontally on
the ground.
5. Measure 10 grain spacings with the ruler
.
6. Calculate the average grain spacing.
K K
K =
K + K + K + + K
K =
+ + + +
Ab1 Ab10
Ab1-10
Ab1 Ab2 Ab3 Ab10
Ab1-10
®
...
...
10
10
CMS-I-00002066
CMS-T-00002354-B.1
6 | Preparing the machine
Preparing the implement for operation
MG6660-EN-II | D.1 | 27.09.2021
91