3 - 24
Feed and rotary module
Application of Disassembly
1 Removal of Inner rotary hook assy
1. Remove the inner rotary hook assy. 1.
1
2 Removal of Needle plate A assy
1. Remove the 2 screw needle plates 1, and then remove the needle plate A
assy. 2.
1
2
2-1 Disassembly of Needle plate A assy
1. Remove the 2 screws 1, and then remove the F gear stopper plate 1 from
the needle plate A 2.
2. Remove the 2 screws 2, and then remove the needle plate B support plate
3 and the stopper plate 4 from the needle plate A 2.
3. Remove the 2 screws 3, and then remove the needle plate holder 5 from
the needle plate A 2.
2 3
1
1 4
32
25
1
3 Removal of Feed dog
1. Remove the 2 screws 1, and then remove the Feed dog 1.
1
1