116 S I G M A with Bluefin



The two ports are interfaced to the
console via a Wide Area Bulk (WAB)
card, which occupies one of the
AES/bulk card slots in the Processing
Rack.
Each MADI interface can operate in
either 56 or 64 channel mode and can
transmit over a coaxial AND optical
medium and receive over a coaxial
OR optical medium. A switch allows
receiver selection.
Sample Rate Conversion is not
available on MADI inputs or outputs,
therefore all equipment connected via
MADI must be synchronised to the
same source as the console.
Once set up, MADI inputs are viewed
and patched on the console in the
same way as AES inputs.

MAdI

MADI
Unit
Power
Fiber Copper
Connection
Max Cable
Length
Connection
Typ. Cable
Length
JM5407 DC (24V) ST - Multi-mode 2 km BNC (75 Ohm) <50 m
J M 5 4 18 AC (100-240V) ST - Multi-mode 2 km BNC (75 Ohm) <50 m
JM5450 DC (24V) SC - Multi-mode 2 km BNC (75 Ohm) <50 m
J M 5 4 5 1 AC (100-240V) SC - Multi-mode 2 km BNC (75 Ohm) <50 m
JM5754 DC (24V) SC - Single-mode 10 km BNC (75 Ohm) <50 m
JM5755 AC (100-240V) SC - Single-mode 10 km BNC (75 Ohm) <50 m