D-7
Scanner
®
2000 microEFM Appendix D
Power Conguration
Register
(Decimal)
Register
(Hex) Description
Data
Type Access Default
1300 514 Power Mode
0 - High Power
1 - Low Power
U16 R/W 1
1301 515 Clock Override U16 R/W 0
1302 516 Internal System Sample Period
[number of seconds between battery
voltage and electronics temperature
measurements]
U16 R/W 3600
1303 517 External Sensor Power Control
Sensor Warmup Time [0 – 2048 sec]
Add 32768 to lock sensor power on.
U16 R/W 32770
Archive Conguration
Register
(Decimal)
Register
(Hex) Description
Data
Type Access Default
1400 578 Archive Reference Number U16 RO 10000
1401 579
Contract Hour
[0-23]
U16 R/W 8 (AM)
1402 57A
Interval Period
[5 seconds to 12 hours]
U16 R/W
3600 seconds
(1 hour)
1403 57B
Partial Records
0 - Not Enabled
1 – Enabled
U16 R/W 0
1404 57C Number of Daily Records U16 RO 768
1405 57D Number of Interval Records U16 RO 2304 (std.);
6392 with
expansion
board
1406 57E Number of Events Records U16 RO 1152
1407 57F Number of Parameters U16 R/W 11
1408 580 Archive Field 1 U16 RO Date
1409 581 Archive Field 2 U16 RO Time
1410 582 Archive Field 3 U16 R/W FR1 Volume
1411 583 Archive Field 4 U16 R/W FR1 Mass
1412 584 Archive Field 5 U16 R/W FR1 Energy
1413 585 Archive Field 6 U16 R/W
Differential
Pressure
1414 586 Archive Field 7 U16 R/W
Static
Pressure
1415 587 Archive Field 8 U16 R/W
Process
Temperature
1416 588 Archive Field 9 U16 R/W FR1 Run Time
1417 589 Archive Field 10 U16 R/W T1 Volume