EasyManuals Logo

Cameron Scanner 2000 microEFM User Manual

Cameron Scanner 2000 microEFM
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #148 background imageLoading...
Page #148 background image
Flow Run 1 Conguration
Register
(Decimal)
Register
(Hex) Description
Data
Type Access Default
3033 BD9 FR1 Pipe Reference Temp FP R/W 68.00 Deg F
3035 BDB FR1 Plate Size FP R/W 1.00 in.
3037 BDD FR1 Plate Reference Temp FP R/W 68.00 Deg F
3039 BDF FR1 Isentropic Exponent - k FP R/W 1.30
3041 BE1 FR1 Viscosity FP R/W 0.010268 cP
3043 BE3 FR1 Cone Beta FP R/W 0.500
3045 BE5 FR1 Cone Flow Coefcient FP R/W 1.000
3047 BE7 FR1 Low Pressure Cutoff FP R/W 1.000 In H2O
3049 BE9 FR1 Specic Gravity FP R/W 0.60
3051 BEB FR1 Heating Value FP R/W 1031.426
3053 BED FR1 Gas Fraction/Quality FP R/W 1.00
3055 BEF FR1 Conguration Parameter 1
(Absolute Density - Liquids)
Liquid Density Base
Fluid = Liquid : Base Density
Fluid = Ngas : Liquid Oil Density
Base
FP R/W 53.06376
3057 BF1 FR1 Conguration Parameter 2
Fluid = Liquid : Flowing Density
Fluid = NGas : Base liquid water
density
FP R/W 62.30385
3059 BF3 FR1 Conguration Parameter 3
Oil Fraction
FP R/W 1.00
3061 BF5 FR1 Conguration Parameter 4 FP R/W 0.00
3063 BF7 FR1 GC - Methane (C1) FP R/W 0.965222
3065 BF9 FR1 GC - Nitrogen (N2) FP R/W 0.002595
3067 BFB FR1 GC - Carbon Dioxide (CO2) FP R/W 0.005956
3069 BFD FR1 GC - Ethane (C2) FP R/W 0.018186
3071 BFF FR1 GC - Propane (C3) FP R/W 0.004596
3073 C01 FR1 GC - Water (H2O) FP R/W 0.00
3075 C03 FR1 GC - Hydrogen Sulde (H2S) FP R/W 0.00
3077 C05 FR1 GC - Hydrogen (H2) FP R/W 0.00
3079 C07 FR1 GC - Carbon Monoxide (CO) FP R/W 0.00
3081 C09 FR1 GC - Oxygen (O2) FP R/W 0.00
3083 C0B FR1 GC - I-Butane (i-C4) FP R/W 0.000977
3085 C0D FR1 GC - N-Butane (n-C4) FP R/W 0.001007
3087 C0F FR1 GC - I-Pentane (i-C5) FP R/W 0.000473
3089 C11 FR1 GC - N-Pentane (n-C5) FP R/W 0.000324
3091 C13 FR1 GC - N-Hexane (n-C6) FP R/W 0.000664
3093 C15 FR1 GC - N-Heptane (n-C7) FP R/W 0.00
3095 C17 FR1 GC - N-Octane (n-C8) FP R/W 0.00
3097 C19 FR1 GC - N-Nonane (n-C9) FP R/W 0.00

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cameron Scanner 2000 microEFM and is the answer not in the manual?

Cameron Scanner 2000 microEFM Specifications

General IconGeneral
BrandCameron
ModelScanner 2000 microEFM
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals