Manual Operation
FACTORY DEFAULT has two options: (1) NO and (2) YES.
When set to FACTORY DEFAULT = NO the instrument will retain the last configuration saved
by the user. If it is set to FACTORY DEFAULT = YES all configuration settings will return to
the factory default.
The screen will display 5 messages: DEVICE MODEL, SERIAL NO., FIRMWARE VERSION,
FPGA VERSION and MODULE VERSION.
Display the model no. 62150H-600S
Display the serial no. 22
Display firmware version 01.11 and the released date Feb 1,
2010
Display the FPGA version no. 01.00,01.00
Display the module version no. 01.00,01.00,01.00
Figure 3-99
3.3.7 CALIBRATION
Chroma 62000H Series DC Power Supplies with Solar Array Simulation provide calibration
functions (1) - (5), the A620028 and A620027 provide calibration functions (1)(2)(3) and the
62020H-150S model provides calibration functions (1) - (7):
(1) VOLTAGE: the actual output voltage (CV mode) and the measurement accuracy.
(2) CURRENT: the measurement accuracy of the current.
(3) CURRENT: the actual output current (CC mode).
(4) APG VOLTAGE: the actual output voltage and the accuracy of the analog V Monitor
under analog voltage control mode.
(5) APG CURRENT: the actual output current and the accuracy of the analog I Monitor
under analog current control mode.
(6) IV VOLTAGE: the actual voltage setting (CV mode) and the measurement accuracy in
SAS mode.
(7) IV CURRENT: the current measurement accuracy in SAS mode.
Follow the procedure below to enter into calibration mode:
1. In the CONFIG Setup page, press ā ā then to enter into the CALIBRATION
option as shown in Figure 3-100.
[ F A C T O R Y D E F A U L T ]
R E C A L L
D E F A U L T = N O _
D E V I C E
M O D E L
: 6 2 1 5 0 H ā 6 0 0 S
S E R I A L N O : 2 2
F I R M W A R E V E R S I O N
: 0 1 . 1 1, F e b 1 2 0 1 0
F P G A V E R S I O N
: 0 1 . 0 0 , 0 1 . 0 0
M O D U L E V E R S I O N : 0 1 . 0 0 , 0 1 . 0 0 , 0 1 . 0 0