167
Appendix II
Linear Imager (CCD), Laser (SE950)
Select Length
One or two fixed lengths
Range
4~127
Matrix 25 Enable
Start/Stop Selection Refer to Industrial 25. Matrix 25
Verify Check Digit Decide whether to verify the check digit. If the check digit
is incorrect, the barcode will not be accepted.
No
Transmit Check Digit Decide whether to include the check digit
in the data being
transmitted.
Yes
Select Length
One or two fixed lengths
Range
4~127
French Pharmacode Disable
Transmit Check Digit Decide whether to include the check digit
in the data being
transmitted.
Yes
Italian Pharmacode (Code 32) Disable
Transmit Check Digit Decide whether to include the check digit
in the data being
transmitted.
Yes
Note: For French/Italian Pharmacode, “Transmit Start/Stop Character” is not provided in
UI but it is controlled by the same setting of Code 39.
Code 39 Enable
Transmit Start/Stop
Character
Decide whether to include the start/stop characters "*" in
the data being transmitted.
No
Verify Check Digit Decide whether to verify the check digit. If the check digit
is incorrect, the barcode will not be accepted.
No
Transmit Check Digit Decide whether to include the check digit
in the data being
transmitted.
Yes
Code 39 Full ASCII Code 39 Full ASCII includes all the alphanumeric and
special characters.
Disable
Code 93 Enable
MSI Disable
Verify Check Digit Select one of the three calculation formulas to verify the
check digit. If the check digit
is incorrect, the barcode will
not be accepted.
Single Modulo 10
Double Modulo 10
Modulo 11 & 10
Single Modulo
10
Transmit Check Digit Decide whether to include the check digit
in the data being
transmitted.
Last digit not transmitted
Both digits transmitted
Both digits not transmitted
Both digits
transmitted