Configuring Regional Parameters and Supplementary Services
Scripting for Cadences, Call Progress Tones, and Ring Tones
Cisco Small Business SPA300 Series, SPA500 Series, and WIP310 IP Phone Administration Guide 193
7
Example 2: Distinctive Ring (short, short, short, long)
60(.2/.2,.2/.2,.2/.2,1/4)
Where:
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 60s
Number of Segments = 4
Segment 1: On=0.2s, Off=0.2s
Segment 2: On=0.2s, Off=0.2s
Segment 3: On=0.2s, Off=0.2s
Segment 4: On=1.0s, Off=4.0s
Total Ring Length=60s
Tone S cript
A ToneScript is a mini-script that specifies the frequency, level, and cadence of a
call progress tone. It can contain up to 127 characters. Syntax:
FreqScript;Z1[;Z2]
Section Zi is similar to the Si section in a CadScript except that each on/off
segment is followed by a frequency parameter: Zi = Di(oni,1/offi,1/
fi,1[,oni,2/offi,2/fi,2 [,oni,3/offi,3/fi,3 [,oni,4/offi,4/
fi,4 [,oni,5/offi,5/fi,5 [,oni,6/offi,6/fi,6]]]]])
where fi,j = n1[+n2]+n3[+n4[+n5[+n6]]]]] 1< nk < 6 indicates which
of the frequency components given in the FreqScript are used in that segment; if
more than one frequency component is used in a segment, the components are
summed together.
Example: Dial Tone
350@-19,440@-19;10(*/0/1+2)
Number of Frequencies = 2
Frequency 1 = 350 Hz at 19 dBm
Frequency 2 = 440 Hz at 19 dBm