Link Setup mode
9390 Reference manual 9-13
To reset some or all of the transceiver settings to their factory
values:
Action Notes
1.
Enter Link Setup mode. See Link Setup mode enter/exit
on page 9-2.
The display shows:
LINK SETUP MENU
1–Pin
2–Inhibit
ENTER
3–Antenna
4–Reset
2.
Enter 4
Chan
4
The display shows:
EXIT
Press F2 to:
RESET
Delete all
unprotected channels
3.
To switch between the
three types of reset, rotate
Select
Select:
Delete all unprotected
channels
’ to delete just
unprotected channels
Reset user settings to
factory defaults
’ to reset
user settings but not
channels
Reset user settings,
delete all channels
’ to
reset user settings and all
channels except factory set
Radphone channels.
Use with caution!