EasyManua.ls Logo

Compaq ProLiant ML570 - 600 - 699, Diskette Drive Test Error Codes; Diskette Drive Test Error

Compaq ProLiant ML570
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics and Troubleshooting 3-27
600 699, Diskette Drive Test Error Codes
The 600 series of diagnostic error codes identifies failures with the diskette, diskette drive, or
system board functions. Corrective action may require replacement of the diskette drive or the
system board assembly.
Table 3-8
Diskette Drive Test Error Codes
Error Code Description Recommended Action
600-XX Diskette ID drive types test failed.
601-XX Diskette format failed.
602-XX Diskette read test failed.
603-XX Diskette write/read/compute test
failed.
604-XX Diskette random seek test failed.
605-XX Diskette ID media failed.
606-XX Diskette speed test failed.
607-XX Diskette wrap test failed.
608-XX Diskette write protect test failed.
609-XX Diskette reset controller test
failed.
610-XX Diskette change line test failed.
694-XX Pin 34 is not cut on 360-KB
diskette drive.
697-XX Diskette type error.
698-XX Diskette drive speed not within
limits.
1. Replace the diskette and retest.
2. Check and/or replace the diskette power and
signal cables, then retest.
3. Replace the diskette drive and retest.
4. Replace the system board and retest.
699-XX Diskette drive/media ID error. 1. Replace the media and retest.
2. Run the Configuration Utility and retest.

Table of Contents