Table 3-19
Event Messages
continued
Event Type Event Message Recommended Action
Processor
Correctable Error
Threshold exceeded
Processor Correctable Error Threshold
passed (Slot X, Socket X)
Replace the processor.
Uncorrectable Error Unrecoverable Host Bus Data Parity Error Replace the processor.
Host Bus Error Unrecoverable Host Bus Address Parity
Error
Call the Compaq authorized service
provider or Compaq technical
support for diagnosis.
PCI Bus Error PCI Bus Error (Slot X, Bus X, Device X,
Function X)
Power down PCI slot and replace
board.
Power Subsystem
Power Supply Failure System Power Supply Failure (Power
Supply X)
Replace power supply.
Power Supply Inserted System Power Supply Inserted (Power
Supply X)
None
Power Supply Removed System Power Supply Removed (Power
Supply X)
None
Power Supply
Not Redundant
System Power Supplies Not Redundant Add power supply.
System Configuration
Battery Low
Real-Time Clock Battery Failing Replace battery.
AC Voltage Problem System AC Power Problem (Power
Supply X)
Check the input power voltage.
Power AC Overload System AC Power Overload (Power
Supply X)
Change the input power
to 220 V.
Add an additional power
supply, or replace with one able
to supply present load.
Reduce the load.
Automatic Server Recovery2
System Stops
Responding
ASR Lockup Detected: Cause Call the Compaq authorized service
provider or Compaq technical
support for diagnosis.
continued