Diagnostics and Troubleshooting 3-69
Table 3-23
ASR-2 IML or Critical Error Log Messages
continued
Message Description
Battery Failing Low system battery warning. Replace battery within 7 days to prevent loss
of nonvolatile configuration memory. Failure of the battery supporting the
system nonvolatile RAM is imminent.
Caution: Temperature Exceeded The operating system detected that the temperature of the system
exceeded the caution level. Accompanying data in the log notes if an
auto-shutdown sequence was invoked by the operating system.
Diagnostic Error An error was detected by the Diagnostics Utility. See the specific error code
in this chapter for a detailed explanation.
Error Detected On Boot Up The server detected an error during the Power-On Self-Test (POST).
NMI Automatic Server
Recovery Timer Expiration
The operating system received notice of an impending ASR-2 timer
expiration.
NMI Expansion Board Error A board on the expansion bus indicated an error condition, resulting in a
server failure.
NMI Expansion Bus Master
Timeout
A bus master expansion board in the indicated slot did not release the bus
after its maximum time, resulting in a server failure.
NMI Expansion Bus Slave
Timeout
A board on the expansion bus delayed a bus cycle beyond the maximum
time, resulting in a server failure.
NMI Fail-Safe Timer
Expiration
Software was unable to reset the system fail-safe timer, resulting in a
server failure.
NMI PCI Bus Parity Error A parity error was detected on the PCI bus.
NMI Processor Parity Error The processor detected a data error, resulting in a server failure.
NMI Software Generated
Interrupt Detected Error
Software indicated a system error, resulting in a server failure.
Processor Exception The indicated processor exception occurred.
Processor Prefailure A CPU passed an internal corrected error threshold; excessive internal ECC
cache errors.
Required System Fan Failure The required system fan failed. Accompanying data in the log notes if an
auto-shutdown sequence was invoked by the operating system.
Server Manager Failure An error occurred with the Server Manager/R board.
UPS AC Line Failure Shutdown
or Battery Low
The UPS notified the operating system that the AC power line failed.
Accompanying data indicates an auto-shutdown sequence was invoked or
the battery was nearly depleted.