Diagnostics and Troubleshooting 3-19
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1789-Drive Not
Responding, Physical
Drive
Check cables or
replace physical
drive X.
Select “F1” to
continue – drive
array will remain
disabled.
Select “F2” to fail
drive(s) that are not
responding.
Interim Recovery
Mode will be enabled
if configured for fault
tolerance.
None Cable or hard drive failure 1. Check the cable
connections.
2. Replace the cables.
3. Replace the drive. If you
do not want to replace the
drive now, press F2.
1790-Disk 0
Configuration Error
None Hard drive error or wrong drive
type
Run the System Configuration
Utility and Diagnostics and
correct.
1791-Disk 1 Error None Hard drive error or wrong drive
type
Run the System Configuration
Utility and Diagnostics and
correct.
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive array.
None Indicates that while the system
was in use, power was
interrupted while data was in the
array accelerator memory. Power
was then restored within 8 to 10
days, and the data in the array
accelerator was flushed to the
drive array.
No data has been lost. Perform
orderly system shutdowns to
avoid data remaining in the
array accelerator.
1793-Drive Array –
Array Accelerator
Battery Depleted –
Data Lost
(Error message 1794
also displays.)
None Indicates that while the system
was in use, power was
interrupted while data was in the
array accelerator memory. Array
accelerator batteries failed.
Power was not restored within 8
to 10 days. Data in array
accelerator has been lost.
Perform orderly system
shutdowns to avoid data
remaining in the array
accelerator.
continued