Diagnostics and Troubleshooting 3-21
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1799-Drive Array –
Drive(s) Disabled due
to Array Accelerator
Data Loss.
Select “F1” to
continue with logical
drives disabled.
Select “F2” to accept
data loss and to
re-enable logical
drives.
None Volume failed due to loss of data
in posted-writes memory.
Press F1 to continue with
logical drives disabled or F2 to
accept data loss and re-enable
logical drive.
Beeps only 2 long No valid memory is present in
the system.
Replace failed memory with
valid memory.
Beeps only 2 long, 2 short Power is cycled. Temperature too
hot. Processor fan not installed
or spinning.
Check fans.
(Run System
Configuration Utility –
F10 key)
None A configuration error occurred
during POST.
Press F10 to run System
Configuration Utility.
(RESUME – F1 key) None An indication to continue with the
operation
Press F1.

Table of Contents