EasyManua.ls Logo

D-Link DFL-870

D-Link DFL-870
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.51. HWMSettings
Description
General settings for Hardware Monitoring
Properties
EnableSensors Enable/disable all HWM functionality. (Default: No)
SensorPollInterval Sensor polling interval. (Default: 500)
MemoryPollInterval Memory polling interval in minutes. (Default: 15)
MemoryUsePercent Should mem monitor use percentage as unit for
monitoring, else it is megabyte. (Default: Yes)
MemoryLogRepetition Should a log message be sent for each poll result
that is in the Alert, Critical or Warning level, or
should a log message only be sent when a new
level is reached. (Default: No)
MemoryAlertLevel Alert log message if free memory is below this
value, disable by using 0. (Default: 0)
MemoryCriticalLevel Critical log message if free memory is below this
value, disable by using 0. (Default: 0)
MemoryWarningLevel Warning log message if free memory is below this
value, disable by using 0. (Default: 0)
Note
This object type does not have an identifier and is identified by the name of the type
only. There can only be one instance of this type.
Chapter 3: Configuration Reference