3.99. RealTimeMonitorAlert
Description
Monitors a statistical value. Log messages are generated if the value goes below the lower
threshold or above the high threshold.
Properties
Index The index of the object, starting at 1. (Identifier)
Monitor Statistical value.
SampleTime Interval in seconds between checking the statistic.
(Optional)
LowThreshold Log if statistical value goes below this threshold.
(Optional)
HighThreshold Log if statistical value goes above this threshold.
(Optional)
BackoffInterval The minimum number of seconds between
consecutive log messages. (Default: 60)
Continuous If set, generate event if the value goes from being
outside the threshold values, back to within
acceptable limits again. (Default: No)
LogMessageID ID of generated log messages. (Optional)
Comments Text describing the current object. (Optional)
Note
If no Index is specified when creating an instance of this type, the object will be placed
last in the list and the Index will be equal to the length of the list.