3.123. StateSettings
Description
Parameters for the state engine in the system.
Properties
ConnReplace What to do when the connection table is full.
(Default: ReplaceLog)
LogOpenFails Log packets that are neither part of open
connections nor valid new connections. (Default:
Yes)
LogReverseOpens Log reverse connection attempts through an
established connection. (Default: Yes)
LogStateViolations Log packets that violate stateful tracking rules; for
instance, TCP connect sequences. (Default: Yes)
LogConnections Log connections opening and closing. (Default:
Log)
LogConnectionUsage Log for every packet that passes through a
connection. (Default: No)
MaxConnections_Dynamic Allocate the Max Connection value dynamically.
(Default: Yes)
MaxConnections Maximum number of simultaneous connections.
(Default: 8192)
Note
This object type does not have an identifier and is identified by the name of the type
only. There can only be one instance of this type.