Barcode Scanning Features
206
DS8110 Barcode Scanner
Learn
Once entered, the LEARN LED blinks and scanner starts a procedure to automat-
ically detect and recognize bar
codes, which are presented to it.
Place a barcode into the scan line and the LEARN LED goes solid for a short time
as Processing and Decoding parameters are successfully saved.
If the calibration cannot be re
ached after a timeout of about 3 (three) minutes,
the scanner will exit Learn Mode without saving the parameters.
Setup
This mode is available in a master/slave system (scanner as master, not an
SC5000.)
This option applies to the last slave scanner in the
daisy-chain system, allowing
its open Ethernet port to work as a dedicated setup port.
In practice, you can always communicate using this
port,
but the Setup Mode
turns off all of the other EBC traffic on that port.
Netconfig
Once entered from a Master scanner in a multi-scanner array (tunnel), the sys-
tem detects and identifies Slave scanners in the array. The Slave scanners (and
the Maste
r) will then be available in e-Genius
(see chapter ).
Press the X-Press button once again to exit.
Restore Button and Other Functions
Function Description
Scanner Replacement
Hold down RESTORE button un
til all LEDs turn on. After all LEDs go off,
then READY LED comes back on. Parameters stored in the CBX510 are
now being used in the scanner.
Software Recovery
Mode
Hold down X-P
r
ess button while scanner is powered up.
Reset Scanner to Fac-
tory Defaults
Hold down X-Pr
ess and RESTORE buttons while scanner powers. When
default is successful, all LEDs will flash 3 times.
By default, the Test exits automatically after two minutes
This option must only be applied to the last slave scanner in the EBC network. Applying
this option to the other slaves will disrupt the EBC network.