EasyManuals Logo

Datalogic DS8100 User Manual

Datalogic DS8100
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #239 background imageLoading...
Page #239 background image
Replacing an Installed DS8110
Reference Manual 227
2. Label the cables attached to ETH1 and/or ETH2 so you can easily identify
where they were connected, then remove the cables.
3. Detach the existing scanner from its mo
unting bracket, leaving the bracket
attached to the mounting structure.
4. Attach the replacement scanner to the mounting bracket.
5. Reattach the power, I/O, ETH1 and/or ETH2 cables.
6. Apply power to the array. The system will
automatically find and download
system parameters to the replacement scanner.
Replacing a Slave Scanner in an Array/Tunnel Using Restore
If the Enable Automatic Slave Replacement check box has NOT been selected and
saved in the system parameters, use the following procedure to replace a slave
scanner:
1. Remove power from the array.
2. Remove the power and I/O cables fr
om the scanner being replaced.
3. Label the cables attached to ETH1 and/or ETH2 so you can easily identify
wh
ere they were connected, then remove the cables.
4. Detach the existing scanner from its mo
unting bracket, leaving the bracket
attached to the mounting structure.
5. Attach the replacement scanner to the mounting bracket.
6. Reattach the power, I/O, ETH1 and/or ETH2 cables.
7. Apply power to the array.
8. Once the scanner has booted up and the READY
LED lights solid green,
press and hold the RESTORE button until all of the LEDs turn on, indicating
that the parameters are being restored from the CBX510’s BM100 backup
module or SC5000 flash memory.
9. Release the RES
TORE button.
Replacing a Master Scanner in an Array/Tunnel Using Restore
1. Remove power from the array.
2. Remove the power and I/O cables from
the Master scanner being replaced.
3. Label the cables attached to ETH1 and/or ETH2 so you can easily identify
wh
ere they were connected, then remove the cables.
4. Detach the existing scanner from its mo
unting bracket, leaving the bracket
attached to the mounting structure.
5. Attach the replacement master scanner to the mounting bracket.

Table of Contents

Other manuals for Datalogic DS8100