V1108, 8.25
Each attribute is indicated by a keyword. The following keywords are possible:
One line in the log file takes approximately 50 bytes, so with a file size of 10 Kilobytes it is
possible to log about 200 events. This can vary, since the description length of one event can
vary.
If a large file is necessary to record a lot of events, it could be wise to use an external USB key
or a network location to store the file. The maximum file size supported by the control is 1
Megabyte (1000 Kilobytes).
Event type Keyword Possible attributes
Mode change mode mode number:
1 = manual
2 = programming
3 = automatic
4 = step by step
Step change step product ID, step number
Control start start product ID, step number and
stock counter
Control stop stop product ID, step number and
stock counter
Product complete prod_rdy product ID, stock counter
Error message error error number
Attribute Keyword
Mode number mode
Bend step number step
Product ID prod
Stock count number stock
Error number error