V1108, 9.5
Hold time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..T
Hold time of punch at the bending point.
Parallelism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..Y2
Difference of left- and right hand side cylinder (Y1 and Y2). When positive right hand
side lower. When negative right hand side higher. The programmed value is active
below the clamping point.
9.d
G-corr. PS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..Gp=
This is a general correction on the angle position of the part support. It is valid for all
bends.
The correction is programmed here as an angle value, relative to the part support angle
of the current bend. The correction is remembered as a percentage of the current angle.
If another bend is programmed or selected with a different angle, the correction value
will be adjusted accordingly.
Only available if a part support is present.
After pushing the start button all the programmed parameters are active.