Table 14. Supported video resolution options (continued)
Resolution Refresh rate (Hz) Color depth (bits)
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1400 x 1050 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32
Environmental specifications
The PowerEdge XR8620t operates in these environmental categories: ASHRAE A2, NEBS3, GR3108C1+, GR3108C1-L and
NEBS3-H.
NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located
with the Documentation > Regulatory Information on Dell Support.
Table 15. Continuous operation specifications for ASHRAE A2
Feature Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
1035°C (5095°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900
m (2953 Ft)
Table 16. Continuous operation specifications for NEBS3
Feature Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
-5° to 55°C (23 to 131°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/80 m (1.8°F/263 Ft) above 900
m (2953 Ft)
Table 17. Continuous operation specifications for GR3108C1+
Feature Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
-20° to 65°C (-4 to 149°F) with no direct sunlight on the equipment. Cold
boot support at - 20°C
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/58 m (1.8°F/190 Ft) above 900
m (2953 Ft)