Table 44. Boot Settings details(continued)
Option Description
NOTE: This option controls the UEFI boot order. The first option in the list will
be attempted first.
Table 45. UEFI Boot Settings
Option Description
UEFI Boot Sequence Enables you to change the boot device order.
Boot Option Enable/Disable Enables you to select the enabled or disabled boot devices
Network Settings
To view the Network Settings screen, power on the system, press F2, and click System Setup Main Menu > System BIOS
> Network Settings.
NOTE: Network Settings are not supported in BIOS boot mode.
Table 46. Network Settings details
Option Description
UEFI PXE Settings Enables you to control the configuration of the UEFI PXE device.
Number of PXE Devices This field specifies the number of PXE devices. This option is set to 4 by
default.
PXE Device n (n = 1 to 4) Enables or disables the device. When enabled, a UEFI PXE boot option is
created for the device.
PXE Device n Settings(n = 1 to 4) Enables you to control the configuration of the PXE device.
UEFI HTTP Settings Enables you to control the configuration of the UEFI HTTP device.
HTTP Device n (n = 1 to 4) Enables or disables the device. When enabled, a UEFI HTTP boot option is
created for the device.
HTTP Device n Settings (n = 1 to 4) Enables you to control the configuration of the HTTP device.
UEFI ISCSI Settings Enables you to control the configuration of the iSCSI device.
ISCSI Initiator Name Specifies the name of the iSCSI initiator in IQN format.
ISCSI Device1 Enables or disables the iSCSI device. When disabled, a UEFI boot option
is created for the iSCSI device automatically. This is set to Disabled by
default.
iSCSI Device1 Settings Enables you to control the configuration of the iSCSI device.
UEFI NVMe-oF Settings Enables you to control the configuration of the NVMe-oF devices.
NVMe-oF Enables or disables the NVMe-oF feature. When enabled, it allows to
configure the host and target parameters needed for fabric connection.
This is set to Disabled by default.
NVMe-oF Host NQN This field specifies the name of the NVMe-oF host NQN. Allowed input is
in the following format: nqn.yyyy-mm.<Reserved Domain Name>:<Unique
String>. Leave it empty to use system generated value with following
format: nqn.1988-11.com.dell:<Model name>.<Model number>.<Service
Tag>. This is set to
nqn.1988-11.com.dell:<model name>.<model
number>.<service tag> by default.
NVMe-oF Host Id This field specifies a 16 bytes value of the NVMe-oF host identifier
that uniquely identifies this host with the controller in the NVM
subsystem. Allowed input is a hexadecimal-encoded string in this format:
00112233-4455-6677-8899-aabbccddeeff. Leave it empty to use system
Pre-operating system management applications 43