Table 18. Continuous operation specifications for GR3108C1-L
Feature Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
-20° to 55°C (-4 to 131°F) with no direct sunlight on the equipment. Cold
boot support at - 20°C
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/80 m (1.8°F/263 Ft) above 900
m (2953 Ft)
Table 19. Continuous operation specifications for NEBS3-H
Feature Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2953 ft)
-5° to 65°C (23 to 149°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/58 m (1.8°F/190 Ft) above 900
m (2953 Ft)
Table 20. Common environmental specifications for ASHRAE A2, NEBS3, GR3108C1+, GR3108C1-L and
NEBS3-H 
Feature Allowable continuous operations
Maximum temperature gradient (applies to both
operation and non-operation).
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15
minutes), 5°C in an hour* (9°F in an hour) for tape hardware
Non-operational temperature limits -40 to 65°C (-40 to 149°F).
Non-operational humidity limits (Non-
Condensing at all times)
5% to 95%RH with 27°C (80.6°F) maximum dew point
Maximum non-operational altitude 12,000 meters (39,370 feet)
Maximum operational altitude 3,050 meters (10,006 feet)
Table 21. Maximum vibration specifications
Maximum vibration Specifications
Operating 0.21 G
rms
at 5 Hz to 500 Hz (all operation orientations)
Storage 1.88 G
rms
at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 22. Maximum shock pulse specifications
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y,
and z axis of 6 G for up to 11 ms (4 pulse on each side on the system)
Storage Six consecutively executed shock pulses in the positive and negative x, y,
and z axis (one pulse on each side of the system) of 71 G for up to 2 ms
Environmental considerations
The PowerEdge system is targeted for edge deployments and it meets all the additional standards for thermal, shock, and
vibration parameters.
Technical specifications
25

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge XR8620t and is the answer not in the manual?

Dell PowerEdge XR8620t Specifications

General IconGeneral
BrandDell
ModelPowerEdge XR8620t
CategoryServer
LanguageEnglish

Related product manuals