DIAGNOSTICS DISPLAYS
The diagnostics functions are always accessible without the need for a password.
From the main screen, press ENTER to enter diagnostics mode.
Then scroll forwards or backwards to select the desired page.
To ease the page search the page number and an identication text are displayed when the page changes.
P02
P100 W 4.1 M5.0
A 45 L 8.5 R6.0
P = Lifting cylinder differential pressure
W = Load read by the system (t)
M = Maximum load allowed in the current position
A = Boom angle
L = Boom extension
R = Radius from fork centre to swing gear centre
P03: Alarms
Alarm xx
Warning xx
Alarm: Present alarm code (0 = non alarm)
Warning: Warning code (0 = Ok)
(4 = Basket detected but corresponding table not selected)
P04: Pressures
P100 L: xxx H: xxx
P40 l: xxx h: xxx
Line above
P = Lifting cylinder differential pressure
L: Pressure base plate side
H: Pressure rod side
Line below
p = Compensation cylinder differential pressure
l: Pressure compensation base plate side
h: Pressure compensation cylinder rod side
P05: Boom
A 11.1 12.2 1.1
L 8.5 8.6 0.1
Main boom extension and angle readings from the winder.
Line above: Angle 1, Angle 2 and difference between the 2 angles
Line below: Extension 1, Extension 2 and the difference
P6: Act1A
ACT1A A:aaaa
ccc Eee L:ssss
Main boom winder: Left transducer
See angle calibration
P7: Act1B
Right transducer
See angle calibration
P08: AI0-3
0 B111 2 B222
1 B333 3 xxxx
0-3 Analogue channel readings
0: Pressure transducer base plate side
1: Pressure transducer rod side
2: Pressure transducer on compensator base plate side
3: Pressure transducer on compensator rod side
P09: AI4-7
4 B111 5 B222
6 B333 7 xxxx
4-7 Analogue channel readings