5.3.7.1 Forward Speed @ Maximum
Parameter Possible Values Default Rev HHP Lite Std Adv
Forward Speed @ Maximum 10 – 100 % N/A -,A,C
Sets the forward speed of the powerchair when the joystick is fully deflected forward
and the Speed Pot is in its Maximum position.
This parameter must be set for every Drive Profile.
GBK60348
: Issue 1 – October 2007
66
See also section
5.3.2.3: Speed setting recommendations.
5.3.7.2 Forward Speed @ Minimum
Parameter Possible Values Default Rev HHP Lite Std Adv
Forward Speed @ Minimum 5 – 100 % 5% C
Sets the forward speed of the powerchair when the joystick is fully deflected forward
and the Speed Pot is in its Minimum position.
This parameter must be set for every Drive Profile.
This parameter partially replaces the
Speed Pot Scaler parameter (see 5.3.9.5).
See also section
5.3.2.3: Speed setting recommendations.
5.3.7.3 Forward Acceleration
Parameter Possible Values Default Rev HHP Lite Std Adv
Forward Acceleration 10 – 70 % 40 % -,A,C
Sets the rate at which the forward speed increases after the joystick has been
deflected forward. 10% results in a very slow increase, 70% results in a very quick
increase.
See also section
5.3.1.3 : Acceleration and deceleration.
5.3.7.4 Forward Deceleration
Parameter Possible Values Default Rev HHP Lite Std Adv
Forward Deceleration 15 – 100 % 60 % -,A,C
Sets the rate at which the forward speed decreases after the joystick has been
returned to the centre. 15% results in a very slow stop, 100% results in an instant stop.
See also section
5.3.1.3 : Acceleration and deceleration.
Warning:
Setting the Deceleration too low or too high can result in an unsafe
powerchair. Test thoroughly after programming to make sure that the
powerchair complies with regulatory requirements such as ISO7176
and the GMD-TND Homologation Directive R04 for maximum
allowable braking distance.

Table of Contents

Other manuals for Dynamic DX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamic DX and is the answer not in the manual?

Dynamic DX Specifications

General IconGeneral
BrandDynamic
ModelDX
CategoryNetwork Router
LanguageEnglish

Related product manuals